Quality Assurance

Quality You Can Verify — Every Batch

From synthesis to shipping, every Peptides Duo product is tested to HPLC ≥99% purity and released only with a Certificate of Analysis — so your research starts from well-characterized material.

Reproducible research depends on reliable material. Our quality system verifies identity, purity and consistency at every step — from raw materials through synthesis, purification and analytical testing to final batch release — and documents the results so you can trust what is in the vial.

Our Approach

Three Principles Behind Every Batch

We keep our quality system practical: reliable data, reproducible manufacturing and traceable records, matched to how the material will actually be used.

Consistency, batch after batch

Quality is built into synthesis and purification, not bolted on at the end. Standardized protocols mean a repeat order looks like the last one — same purity window, same analytical profile.

Data you can read

We report the numbers that matter — HPLC purity, confirmed mass, net peptide content — in a Certificate of Analysis that is straightforward to check, not buried in jargon.

A traceable path

Every released batch links back to its production and analytical records, so material can be traced, questioned and re-tested when your work depends on it.

Our Process

How Every Batch Is Made and Verified

1

Solid-Phase Synthesis

Every peptide is assembled by automated solid-phase synthesis with controlled coupling and deprotection, so sequences are built reproducibly across production scales.

2

Crude Analysis

The crude peptide is screened by HPLC before purification, so process issues are caught early rather than at final release.

3

Preparative HPLC Purification

Reversed-phase preparative HPLC removes truncated sequences and process impurities, driving the material toward our ≥99% purity target.

4

LC-MS Identity Confirmation

Molecular weight is confirmed by LC-MS against the theoretical sequence, so you know the vial contains the peptide you ordered.

5

Purity & Content Testing

Analytical HPLC quantifies final purity; net peptide content, appearance and solubility are checked and recorded for the batch.

6

Final QC Review & COA

Results are reviewed against specification, a Certificate of Analysis is issued, and retained samples support later traceability and re-testing.

What We Test

Analytical Checks on Every Batch

Each batch is characterized across the following parameters before release, with extended testing available where an application calls for it:

  • HPLC purity — target ≥ 99% by peak-area normalization
  • Identity — molecular weight confirmed by LC-MS
  • Net peptide content — measured and reported per batch
  • Appearance — white to off-white lyophilized powder
  • Solubility & reconstitution guidance for common solvents
  • Water content by Karl Fischer titration (on request)
  • Residual solvents by GC, referencing ICH Q3C (on request)
  • Endotoxin (LAL) and microbial limits for sensitive applications (on request)
Purity Standards

Purity Grades We Supply

Purity is calculated by peak-area normalization under validated HPLC conditions. Choose the grade that matches your application — our standard offering targets ≥99%.

GradeTypical HPLC purityBest suited for
Research grade≥ 95%General laboratory and screening work
Standard grade≥ 98%Most quantitative research applications
High-purity grade≥ 99%Sensitive assays and reference material
Premium batches≥ 99.5%Projects with the strictest purity requirements

Purity figures are typical targets; the exact value for your batch is stated on its Certificate of Analysis.

Analytical Methods

How We Characterize Each Peptide

A combination of chromatographic, mass-spectrometric and physicochemical methods is used to characterize identity, purity and quality. Not every test applies to every product — extended testing is applied where the application requires it.

HPLC Purity Analysis

Reversed-phase analytical HPLC is our primary purity method. Purity is calculated by peak-area normalization under controlled chromatographic conditions, and each chromatogram is reviewed before the batch is released.

LC-MS Identity Confirmation

Liquid chromatography–mass spectrometry confirms that the measured molecular weight matches the target sequence and flags truncated or modified impurities. A clear dominant molecular-ion peak is required before release.

Residual Solvents (ICH Q3C)

Where relevant, residual solvents such as acetonitrile, DMF and dichloromethane are measured by gas chromatography, referencing ICH Q3C limits, and reported in the batch record.

Endotoxin Testing (LAL)

For peptides intended for cell-based or biological work, endotoxin can be quantified by the Limulus Amebocyte Lysate assay to a research-grade specification, with tighter limits available on request.

Microbial Limits (USP)

When required, microbial limit testing follows USP <61> and <62> principles — total aerobic count, yeast and mould, and pathogen screening where applicable.

Water Content (Karl Fischer)

Water content in lyophilized material is measured by Karl Fischer titration, an important factor for stability and accurate net-content calculation.

Laboratory

Analytical Instruments We Use

Testing is carried out on maintained, calibrated instrumentation dedicated to peptide analysis:

  • Analytical and preparative HPLC systems
  • LC-MS for high-resolution molecular-weight confirmation
  • Gas chromatography for residual-solvent analysis
  • Karl Fischer titrators for moisture determination
  • UV detection integrated into chromatographic systems
  • Controlled cold storage for retained samples and reference material
Peptides Duo analytical laboratory
Batch Release

The Steps Before a Batch Ships

No batch is released on a single test. Results pass through a short, structured review before the material leaves our facility:

1

2 · Data verification

Chromatograms and mass spectra are cross-checked to confirm the results are complete and consistent.

2

1 · Internal QC review

HPLC purity and LC-MS identity results are checked by the QC team against the method requirements.

3

3 · Specification review

Results are compared against the project or product specification for that peptide and grade.

4

4 · Final approval

A batch is released only after sign-off, so nothing ships without a documented pass.

5

5 · Documentation issued

The Certificate of Analysis and supporting reports are prepared and shipped with the order.

Documentation

Documents Provided With Your Order

Full analytical documentation accompanies every batch, with additional reports available on request.

Certificate of Analysis (COA)

Issued for every batch: product name, batch number, HPLC purity, confirmed mass, net peptide content and recommended storage.

HPLC Chromatogram

The analytical HPLC trace behind the reported purity figure, available on request.

Mass Spectrometry Report

The LC-MS report confirming peptide identity, available on request.

Additional Reports

Water content, residual solvent, endotoxin or microbial data can be provided where the application calls for it.

Stability & Storage

Keeping Material at Its Best

Correct storage protects the purity you paid for. General guidance is below; sequence-specific advice is available on request.

Lyophilized powder

Store at -20°C in a sealed, dry container for long-term stability; most lyophilized peptides are robust under these conditions.

Short-term handling

Keep at 2–8°C and protect from moisture when handling over short periods; return to the freezer promptly.

After reconstitution

Reconstituted peptide is best kept refrigerated and used within a short window; aliquot to avoid repeated freeze–thaw cycles.

Stability factors

Sequence, hydrophobicity and any modifications influence stability; we provide handling guidance on request for sensitive sequences.

Standards

Regulatory Alignment

Peptides Duo supplies research and industrial peptides — not finished pharmaceutical drugs — but our quality system is designed with reference to recognized standards to support high-standard R&D:

  • ICH guidelines referenced for residual solvents (Q3C) and analytical practice
  • USP general chapters <61> and <62> applied for microbial limits when required
  • Internal validation and documented analytical procedures
  • Alignment with common pharmaceutical-industry analytical practice
FAQ

Quality — Frequently Asked Questions

What is your peptide purity standard and how is it guaranteed?

Our standard research-grade peptides are ≥98% or ≥99% pure (HPLC). As an integrated manufacturer, we fully control the process from synthesis to purification. Every batch undergoes HPLC purity testing and mass spectrometry (MS) identity confirmation to ensure batch consistency.

What is a COA and how can I obtain the batch-specific COA?

A Certificate of Analysis (COA) is a batch-specific report that includes purity, molecular weight, batch number, and testing date. You can view it on the product detail page of our website or request it from your sales representative. HPLC chromatograms and MS data are also available upon request.

What is the practical difference between 95% and 99% purity?

Higher purity means fewer impurities and more reliable experimental results. High-purity grades are suitable for impurity-sensitive research or high-end applications. For most standard research, we recommend ≥98% or ≥99%. Purity levels can be customized according to your needs.

Do you support third-party testing reports?

Yes. We support customer testing. In addition to our internal QC, we can coordinate with customer-designated third-party laboratories (such as Janoshik, Chromate, or Freedom) for verification to further enhance confidence.

Need Documentation for a Specific Batch?

Send us the product and batch number — we will provide the COA and analytical reports you need.